Work out a pressure vessel’s hazard level
Enter the design pressure, volume and contents to get the hazard level under AS 4343:2014. The result updates as you type and shows each step, so you can check the working.
Loading the calculator…
APEC’s in-service pressure equipment inspectors hold AICIP qualifications. Ask one to check this hazard level against your vessel’s data.
General information only, not engineering advice. Confirm with a competent person or your regulator.
Results are free and never need your details. To improve these tools we record the values entered and the result, with no names, email addresses or IP addresses. See our Privacy Policy.
A calculator gives you a number. An inspector tells you what it means.
A hazard level depends on details a calculator cannot see: the vessel’s data report, its contents and how it is used. APEC can review the result with you and advise on the inspection that follows.
NATA accredited
APEC Inspection is accredited by NATA to ISO/IEC 17025:2017 for its non-destructive testing techniques.
AINDT-certified technicians
Our NDT technicians are certified to ISO 9712 through the Australian Institute of Non-Destructive Testing (AINDT).
AICIP-qualified inspectors
Our in-service pressure equipment inspectors hold qualifications with the Australian Institute for the Certification of Inspection Personnel (AICIP).
How this calculator works
AS 4343:2014 ranks pressure equipment from hazard level A (highest) to E (lowest). The level comes from a hazard value, H, that combines the energy a vessel can store with what it contains and how it is used.
- Convert the pressure. The design pressure is converted to MPa, whichever unit you enter.
- Work out PV. Pressure in MPa multiplied by volume in litres gives PV in MPa·L, a measure of the energy the vessel can store.
- Apply the factors. H = P × V × Fc × Ff × Fs. Fc reflects the state of the contents (a gas stores far more energy than a liquid at the same pressure), Ff reflects how harmful the contents are if released, and Fs reflects special service conditions.
- Build Fs. Fs starts at 1. One special condition multiplies it by 3, and two or more by 10. The transportable and human-occupancy conditions are counted on their own rather than added to fired equipment, quick-actuating closures and major hazard facilities. A design pressure above 50 MPa applies a further factor of 30. Mitigating conditions reduce Fs to a third (one) or a tenth (two or more), except for fired equipment.
- Read the level. H is placed in the AS 4343:2014 bands, from A to E. A value exactly on a band boundary takes the lower level.
For three worked examples, see our guide to calculating a hazard level.
The way the calculator combines the Fs conditions is our reading of the standard. Check it, and the factor values, against your own copy of AS 4343:2014.
The hazard level is one of the things WHS regulators use to decide whether a vessel’s design, and the vessel itself, must be registered. It does not set an inspection interval. In-service inspection is planned under AS/NZS 3788 and depends on the vessel’s condition and service.
Assumptions and limits
- Uses the formula method only. Clauses that set a hazard level directly for particular equipment, the rules for vessels with more than one chamber, and the treatment of piping are not applied.
- Enter design values, not operating values, and the vessel’s internal volume in litres.
- Air is generally treated as non-harmful only within a set temperature range. Check AS 4343 for very cold or hot service, or contaminated air.
- The calculator asks how many of the standard’s mitigating conditions apply rather than listing them, so check them against your copy of AS 4343:2014.
- Results use the AS 4343:2014 bands, the edition referenced in WHS regulations at the time of writing. A newer edition has reportedly been published. If your regulator adopts it, results near a band boundary may change.
- Registration notes are general. Requirements and exemptions differ between states and territories.
Frequently asked questions
What is an AS 4343 hazard level?
It is a ranking from A to E that AS 4343:2014 gives pressure equipment, based on the harm that could result if it failed. Level A is the highest hazard and level E the lowest. The level is worked out from a hazard value H that combines pressure, volume, the state and harmfulness of the contents, and special service conditions.
Which pressure should I enter?
Use the design pressure from the vessel's nameplate, data report or design calculations, not the normal operating pressure. You can enter kPa, bar, MPa or psi, and the calculator converts the value to MPa before calculating.
Why does my hazard level differ from what PV alone suggests?
PV only measures stored energy. The fluid state, fluid hazard and special service factors can raise or lower H by large multiples, so two vessels with the same PV can sit in different levels. The hazard level is set by H, not PV.
Does hazard level E mean a vessel needs no inspection?
No. A lower hazard level generally means fewer registration requirements, but WHS laws still require plant to be maintained and inspected so that it is safe to use. What inspection is needed depends on the vessel's condition, service and the standards that apply to it.
Which edition of AS 4343 does the calculator use?
It uses the hazard level bands in AS 4343:2014, the edition referenced in WHS regulations at the time of writing. A newer edition has reportedly been published. If your regulator adopts it, some results near a band boundary may change, so check the edition that applies to you.
Can APEC check the hazard level of my vessel?
Yes. APEC's in-service pressure equipment inspectors hold AICIP qualifications and can review your calculation against the vessel's data. Use the inspector check button to send us the calculation, or call (02) 4062 0305.
Related services and guides
- How to calculate a hazard levelThe formula and three worked examples
- Pressure vessel inspectionIn-service inspection to AS/NZS 3788 by AICIP-qualified inspectors
- AS/NZS 3788: a simple guideWhat in-service pressure vessel inspection involves
- AS/NZS 1200, AS 4343, AS 4037 and AS 3920How the pressure equipment standards fit together
- Hydrostatic testingPressure testing of vessels, piping and components
- All calculatorsPhased array focal effect and AS/NZS 1554.1 weld assessment