Assess RT or UT indications on a Category SP weld
Enter the weld length, the thinner parent thickness and each indication. The calculator applies the AS/NZS 1554.1:2014 weighting method and draws the weld to scale so you can see what drives the result.
Loading the calculator…
APEC’s NDT technicians are certified to ISO 9712 through AINDT. Ask us to review your RT or UT results against AS/NZS 1554.1.
General information only, not engineering advice. Confirm the result with your inspector, the design engineer or the principal.
Results are free and never need your details. To improve these tools we record the values entered and the result, with no names, email addresses or IP addresses. See our Privacy Policy.
A calculator gives you a number. An inspector tells you what it means.
Weld acceptance depends on details a calculator cannot see: how the weld was examined, how indications were sized and the contract requirements. APEC can review your RT or UT results against AS/NZS 1554.1.
NATA accredited
APEC Inspection is accredited by NATA to ISO/IEC 17025:2017 for its non-destructive testing techniques.
AINDT-certified technicians
Our NDT technicians are certified to ISO 9712 through the Australian Institute of Non-Destructive Testing (AINDT).
AICIP-qualified inspectors
Our in-service pressure equipment inspectors hold qualifications with the Australian Institute for the Certification of Inspection Personnel (AICIP).
How this calculator works
This is our description of the method AS/NZS 1554.1:2014 uses for imperfections found by radiography or ultrasonic testing on Category SP welds. Check each step against your own copy of the standard.
- Cracks. Any crack means the weld does not comply.
- Porosity and suspected lamellar tearing. These are not scored here. They are flagged for you to record and refer to the principal (the client or their engineer).
- Heights. Radiography and routine UT do not measure imperfection height, so each height is taken as 2 mm. If heights were sized by UT or by sectioning, tick the box and enter them.
- Combine close imperfections. Working along the weld, two imperfections closer together than the length of the shorter one are treated as one. The combined length runs from the start of the first to the end of the last, gap included, and takes the higher weighting. Chains of three or more combine the same way.
- Weight each imperfection. A weighting factor is set by the thinner parent thickness t and the imperfection height h. Some combinations of t and h are not permitted at all, and the weld then does not comply.
- Compare with the limit. The weighted lengths (length × weighting) are added up. The total must be less than the maximum level for that thickness, a fraction of the weld length that rises from L/5 through L/4 and L/2 to L as t increases. A total equal to the limit does not comply.
- Long welds. For welds over 1,000 mm, every 1,000 mm length of weld is checked against a limit based on 1,000 mm, and the worst window decides the result.
- Weld ends. Within a distance t of either end, an imperfection’s height must not exceed 2 mm or t/20, whichever is larger.
The weld map is drawn to scale: end zones are shaded, combined groups are bracketed and, on long welds, the worst 1 m window is outlined.
Assumptions and limits
- Covers Category SP acceptance for imperfections found by RT or UT only. Category GP, visual examination criteria and porosity assessment are not covered.
- When imperfections combine, the group takes the higher weighting. This is a conservative reading; confirm it against your copy of the standard and with the principal.
- Groups are built one indication at a time: the next indication is compared with the combined group’s length, not only with the indication before it. This combines indications more often than a pair-by-pair reading, so it is conservative.
- On welds over 1,000 mm, windows are placed at both ends of the weld and at each group to find the worst case. Where a group crosses the edge of a window, only the part inside the window counts towards that window’s total (pro rata).
- Indications must come from RT or UT performed and reported by qualified NDT personnel. The calculator assumes the type, position, length and height of each indication are correct, and does not interpret radiographs or UT data.
- Contract documents or the principal may set different acceptance criteria. Where they do, those govern.
- Up to 30 indications per assessment.
Frequently asked questions
What does Category SP mean in AS/NZS 1554.1?
AS/NZS 1554.1 has two weld categories, GP (general purpose) and SP (structural purpose). The designer or principal nominates the category, usually on the drawings. This calculator applies only the Category SP limits for imperfections found by radiography or ultrasonic testing.
Why are imperfection heights taken as 2 mm?
Radiographs and routine ultrasonic testing do not reliably measure how tall an imperfection is through the thickness, so the method takes the height as 2 mm. If heights have been measured by ultrasonic sizing or by sectioning, tick the sizing box and enter them.
When are two imperfections combined?
When the gap between them is less than the length of the shorter one. They are then treated as a single imperfection whose length includes the gap. The calculator applies this along the whole weld, so three or more close imperfections can form one group.
How are welds longer than one metre assessed?
Each 1,000 mm length of weld is assessed on its own and the worst one decides the result. The calculator checks windows along the weld to find the worst position and outlines it on the weld map.
Why is porosity flagged instead of scored?
This calculator does not assess porosity. It flags porosity and suspected lamellar tearing so you can record them and refer them to the principal for a decision under the standard and the contract documents.
Can APEC review our radiographs or UT results?
Yes. APEC provides independent radiographic film interpretation and ultrasonic testing, and its NDT technicians are certified to ISO 9712 through AINDT. Use the inspector check button to send this assessment, or call (02) 4062 0305.
Related services and guides
- Welding procedure and qualificationProcedure and welder qualification support
- AS/NZS 1554.1 explainedStructural steel welding to AS/NZS 1554.1
- Independent film auditingThird-party radiographic film interpretation
- Ultrasonic inspectionUT of welds, plate and components
- Destructive weld testing vs NDTWhen each approach is used
- All calculatorsAS 4343 hazard level and phased array focal effect